This high current switching mode DC regulated output power supply is designed with a highly efficient active power factor corrector. The constant current limiting protection allows the output current to remain stable but the output voltage decreases to a level that permits safe operation of the power supply.
The remote sensing terminals are used to compensate for output line losses so that a precise regulation can be achieved for critical voltage application away from the power supply. The output voltage level and ON-OFF can be externally controlled via the remote terminal.
It is ideal for applications that need good quality high DC current network with precise point of voltage regulation. SPS-9600 has a small footprint for its 900W continuous maximum power. It is suitable for a wide range of applications such as street blaster super high power car audios demonstration console, radio equipment and etc.
- Total max. continuous output current 60A (SPS-9600)
- Main Output / Remote Sensing / Remote Control / terminals at the back
- Front terminals 5A (SPS-9600) limiting
- Adjustable output voltages 1 to 15Vdc (SPS-9600) /
- Remote Sensing for remote point of regulation
- Remote control terminals for output voltage adjustment and *on/off*
- Light weight and small size
- Overload / Over-temperature / Short Circuit Protections
- Constant Current Limiting Protection with LED indicator showing overloading
- Variable speed thermally controlled fan
- High RFI stability
- Active Power Factor Correction (P.F. > 0.97)
| |
SPS-9600
|
SPS-9602
|
| Variable Output Voltage |
1 - 15 V DC
|
1 - 30 V DC
|
| Total Rated Output Current ( Main output + Front Output ) |
60A
|
30A
|
| Rated Output current ( Main Output ) |
60A
|
30A
|
| Rated Output Current ( Front Output ) |
5A
|
3A
|
| Load Regulation ( Main Output ) |
0.1% + 5mV
|
| Line Regulation ( Main Output ) |
0.05% + 3mV
|
| Ripple & Noise ( peak-peak ) |
50mV p-p
|
| Input Voltage |
230V AC / 50Hz (or on request)
|
| Efficiency |
> 85%
|
| Meter Type |
LED Meter
|
| Voltmeter Range |
3 digit display
|
| Ammeter Range |
3 digit display
|
| Meter Accuracy |
± 1% +1 count
|
| Protection Devices |
Overload (Constant Current Limiting), Short Circuit, Over Temperature, OVP
|
| Cooling System |
Variable Speed Thermally Control Fan
|
| Special feature |
Remote Sensing, Remote output voltage control and *on/off*
|
| Approvals |
CE-EMC : EN 55022, CE-LVD: EN 60950 |
| Dimensions ( W x H x D ) |
220 x 110 x 360 (mm) |
| Weight |
5.8 Kgs |
| Remarks |
Power factor correction >= 0.97 at optimal load |
|